CIRCUIT DESIGN, INC.competence in radio solutions

SEARCH

HOMEProductsRF Technical ResourcesSample Order

  TX/RX  |  Transceiver  |  Audio  |  Modem  |  Accessories  |  Selection  |  Compliance  |  Applications

scope products Data rate and frequency

Data module
Circuit Design's RF modules contain all the high frequency components required for transmitting data. All these components are shielded by the metal case.
Specific protocols are not incorporated. Your own original protocol can be used, but must follow the requirements of maximum pulse width.
Digital coding such as Manchester coding is recommended for meeting the maximum pulse requirement. 

Common specs : Narrow band radio / EN300220, EN301489 compliance / FSK modulation
 Transmitter and receiver
Model CDP-TX04S-R
CDP-RX-03BS/AS-R
CDP-TX-02E(P)-R
CDP-RX-02E(P)-R
CDP-TX-02F(P)-R
CDP-RX-02F(P)-R

Click the image for details

CDP-TX04S-R CDP-TX-02E(P)-R CDP-02-F-R
Type Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
CE certificate Yes Yes Yes
RoHS Yes Yes Yes
RF 
Frequency 433.920 MHz(BS-R)
434.075 MHz(BS-R)
869.750 MHz(AS-R)
434 MHz band
or
458 MHz band
434 MHz band
Channel 1 32 (434 MHz)
11 (458 MHz)
128 (12.5 kHz step)
Ch spacing 25 kHz 25 kHz 25 kHz
RF power 10 mW (434 MHz)
5 mW (869 MHz)
1/10 mW selectable 1/10 mW selectable
Data input Digital 
(max.pulse width 20 ms)
Digital 
(max.pulse width 20 ms)
Digital 
(max.pulse width 20 ms)
RX Sensitivity
(12 dB / SINAD)
-120 dBm (434 MHz)
-117 dBm (869 MHz)
-120 dBm -120 dBm
Data rate 4800 bps 4800 bps 4800 bps

Supply power

Supply voltage 2.2 to 5.5 V (TX)
3.0 to 14 V (RX)
3.0 to 12 V (TX)
3.0 to 12 V (RX)
3.0 to 12 V (TX)
3.0 to 12 V (RX)
Supply current 22 mA / TX
21 mA / RX (AS-R)
16 mA / RX (BS-R)
43 mA / TX
30 mA / RX
43 mA / TX
30 mA / RX
Operating temp. range (C.) -10 to 60 -20 to 60 -20 to 60
Physical dimensions 
Size (mm) 22 x 12 x 6 / TX
36 x 26 x 8 / RX
36 x 26 x 10 / TX
50 x 30 x 9 / RX
36 x 26 x 10 / TX
50 x 30 x 9 / RX
Weight 3.4 g / TX
12 g / RX
14 g / TX
20 g / RX
14 g / TX
20 g / RX
 

 Transceiver

Model STD-302N-R
Click the image for details STD-302N-R
Type Transceiver
CE certificate Yes
RoHS Yes *

RF 

Frequency 434 MHz band
869 MHz band
others
Channel Programmable
Ch spacing 25 kHz
RF power 10 mW (434 MHz)
5 mW (869 MHz)
Data input Digital 
(max.pulse width 5 ms)
RX Sensitivity
(12 dB / SINAD)
-119 dBm (434 MHz)
-116 dBm (869 MHz)
Data rate 9600 bps
Supply power
Supply voltage 3.0 to 5.5 V
Supply current 44 mA / TX (434MHz)
26 mA / RX (434MHz)
Operating temp. range (C.) -20 to 60

Physical dimensions 

Size (mm) 50 x 30 x 9
Weight 25 g

* STD-302N-R  RoHS for 434 MHz,869 MHz,and 458 MHz version

 
 
Modem
MU-1 and CCR (Command Controlled Radio) unit provide simple dedicated commands for modem control and the data communication. By using dedicated commands, you can change the RF channel, System ID and UART parameter, and make the data transmission easily. Optional interface boards are available for the CCR and the MU-1 

Common specs : Narrow band radio 25 kHz step / FSK modulation 
                          EN300220, EN301489 compliance
Model MU-1 CCR-STD-302

Click the image for details

MU-1 CCR-STD-302
Type Transceiver modem Transceiver modem
RoHS Yes No

Interface

Synchronization Asynchronous/UART Asynchronous/UART
Max. data rate 57.6 kbps 57.6 kbps
Flow control RS/CS hardware RTS/CTS hardware
Max. data size per 
transmission
255 Byte 255 Byte
Data buffer   255 Byte/TX
255 Byte/RX
RF
RF module equipped   STD-302
Frequency 434 MHz band 434 MHz band
869 MHz band
Channel 64 64 (434 MHz)
80 (869 MHz)
RF power (mW) 10 mW 10 mW (434 MHz)
5 mW (869 MHz)
Radio data rate 9600 bps 9600 bps

Supply power

Supply voltage 3.0 to 5.0 V 3.3 to 5.0 V
Supply current 46 mA /TX
32 mA /RX
45 mA /TX (434 MHz)
30 mA /RX (434 MHz)
43 mA /TX (869 MHz)
30 mA /RX (869 MHz)
Operating temp. range -20 to 60 -10 to 55 

Mechanical dimension

Size (mm) 50 x 30 x 9  53 x 35 x 15.1
Weight 23.5g 38 g

Interface board

  RS232C interface
USB interface
LAN interface
RS232C interface

 
 
Apllication specific module
These radio modules are built with RF circuitry, with the interface circuit matched with the specific application.
The telecommand radio module CDT is designed to meet the requirements of switching signal transmission for Telecotrol applications.
The wireless audio module is designed to meet the requirements of high quality signal transmission for audio applications.

Model CDT-TX-01
CDT-RX-01A
Model WA-TX-01-R
WA-RX-01A-R

Click image for
the details

CDT-TX-01/CDT-RX-01A

Click image for
the details

WA-TX-01-R/WA-RX-01A-R

Type Transmitter
Receiver
Type Transmitter
Receiver
RoHS No RoHS Yes
Application Switching signal transmission Application Audio signal transmission
Interface Interface
I/O 6 switch input /output I/O Analogue input/output
RF  RF 
Frequency 434.075MHz Frequency 863.125MHz
864.625MHz
864.500MHz
864.875MHz
Channel 1 Channel 1
RF power 10 mW RF power 2 mW
Modulation MSK Modulation Variable reactance modulation
Tech. standard  EN 300 220
EN 301 489
Tech. standard  EN 300 422
EN 301 357
EN 301 489
    Freq. response 50Hz to 15kHz
    S/N 90dB 
Supply power Supply power
Supply voltage 2.2 to 12.0 /TX
3.0 to 12.0 /RX
Supply voltage 3 to 9 /TX
3 to 12 /RX
Supply current 25 mA /TX
1 uA /Stand-by
25 mA /RX
Supply current 25 mA /TX
30 mA /RX
Operating temp. range -20 to 60 Operating temp. range 0 to 50
Mechanical dimension Mechanical dimension
Size (mm) 36 x 26 x 8 / TX
53 x 35 x 12 / RX
Size (mm) 27 x 19 x 5.5 / TX
36 x 26 x 8 / RX
Weight 15g/ TX
35g/ RX
Weight 5g /TX
15g /RX
apllication image apllication image


CIRCUIT DESIGN, INC.
Phone:++81-263-82-1024  FAX:++81-263-82-1016  E-mail: